Farzin Kamangar wrote:
> Dear EMC users,
>     I am going to use the Z pulse of my servo motor in order to go home with
> the flag HOME_USE_INDEX = YES. Now my question is: where should I connect my
> index pulse
> as an input? Do I have to use a HAL encoder and set its
> encoder.0.index-enable bit to YES or what. What is the simplest way to use
> the index pulse rising edge instead of the home switch rising or falling
> edge for latching?
What are you using to read the encoder now?  Is is a step/direction 
drive like a Gecko 320?
If so, there may be problems with electrical noise between the servo 
drive and the computer.
Without a software or hardware encoder function reading the full (A B Z) 
encoder output,
this probably will not work.  The EMC home to index function works by 
setting the encoder
counter to zero when index-enable is true and the index pulse is seen.  
You can't just wire up
the index signal ONLY and have this scheme work, as far as I know.

Jon

------------------------------------------------------------------------------