On Sun, 2011-10-02 at 22:53 -0700, Kirk Wallace wrote:
... snip
> Taking a wild guess I tried an ioaddr_hi at extended+2 and it loads
> fine, shows and retains pin and parameter settings, but no output.
... snip

I tried my Pico UPC on the same SIIG parallel port that I used above for
the Pluto. It loads and seems to run okay. I can turn the SSR's on and
off, but I get some error messages from AXIS shown here:
http://www.wallacecompany.com/machine_shop/EMC2/Screenshot-UNIVPWM-1a.png 

The univdiags run fine. I guess this means the trouble with the Pluto is
in the Pluto driver and not in the parport or generic software?

Jon, the Base and the Extended registers on my SIIG happened to be 0x400
apart, does the current driver and diags have a means for finding and
using extended registers in non-standard locations?

I assume the "mode 4" error indicates an EPP problem, but the SIIG
extended control register shows it set for EPP. Although, thinking a
little more, I'm not totally sure parport3 is the SIIG, two ports are
NetMos, the other is the motherboard port.

-- 