On Wed, Feb 13, 2013 at 11:59 AM, Gene Heskett <ghesk...@wdtv.com> wrote:

> My point was, and still is, that relays & switches, unless mercury wetted,
> are generally dirty at both operations
>

Contactors do not 'bounce' on open.  Esp w/ inductive loads;)

An enable signal to the drive is NOT safe w/ DC servos.  When the
transistors fail, they will apply full voltage to the motor.  The only
surefire way to stop them is disconnect the motor or disconnect DC power
from the bridge.