2014-10-10 16:18 GMT+03:00 Dave Cole <linuxcncro...@gmail.com>:
> I'm sure I am not the only one doing this, so how do others start over
> after a program stop when a g92 offset has been used?

So far I always taught my customers to use G54, I actually never
thought about using G92 for setting origin of part coordinates.
Is there any reason not to use G54 or whatever part coordinate
systems? That is exactly what they are meant for, they are easy to set
with touch-off (there is keyboard shortcut) and can be set with G10
L20 command as well from MDI or g-code file.