Could you please check what this does? G91 A360 X0 F100 this has an X component ( no distance tho ) thanks TomP
On 06/24/2015 01:24 PM, Len Shelton wrote: > On a machine with a rotary A axis, if I run > > G91 A360 X10 F100 > > the machine moves 100IPM on the X and the A axis completes a 360 > degree rotation at the same time. If I then run > > G91 A360 F100 > > the machines takes almost 2.5 minutes to complete the rotation, because > it is only running 100 degrees per minute. > > So it seems that the feedrate of the linear axis overrides the feedrate > of the angular units if a linear move is coordinated with it. Can > someone confirm this? > > Also, this becomes a problem for a CAM program like Aspire when it has > an angular move without a simultaneous linear move. I was wondering if > anyone had run across this or if anyone had any thoughts. > > >Len > > > > ------------------------------------------------------------------------------ > Monitor 25 network devices or servers for free with OpManager! > OpManager is web-based network management software that monitors > network devices and physical & virtual servers, alerts via email & sms > for fault. Monitor 25 devices for free with no restriction. Download now > http://ad.doubleclick.net/ddm/clk/292181274;119417398;o > _______________________________________________ > Emc-users mailing list > [email protected] > https://lists.sourceforge.net/lists/listinfo/emc-users > ------------------------------------------------------------------------------ Monitor 25 network devices or servers for free with OpManager! OpManager is web-based network management software that monitors network devices and physical & virtual servers, alerts via email & sms for fault. Monitor 25 devices for free with no restriction. Download now http://ad.doubleclick.net/ddm/clk/292181274;119417398;o _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users