On 01/24/2017 02:31 PM, Gene Heskett wrote:
> On Tuesday 24 January 2017 12:47:01 Jon Elson wrote:
>   Note that
> stepper motors are rated on holding torque, and they will
> not even produce that much when running at low speeds.
> Servos draw no current at no load, and can stay cool so they
> have a reserve or peak torque available.  The torque peak
> can often be 4 - 6 X the continuous rated torque.  So, a
> motor rated at 100 Oz-In continuous could easily deliver 400
> Oz-In peak for a few seconds.
>
> Jon
> Thats a consideration I hadn't plugged into my train of thought Jon,
> thanks.
>
>
But, this is one of the most IMPORTANT features of servo 
motor systems!

Jon

------------------------------------------------------------------------------