Is there a provision for tool setting a face mill or a tool with a different center height than the outside diameter? Or do those have to be done manually? I imagine the spindle orientation would also matter for most tool setters due to the spacing of the inserts.
Matthew Herd [email protected] 610-608-8930 > On Nov 16, 2021, at 7:24 AM, Les Newell <[email protected]> wrote: > > Sorry for the delay in replying. I missed your post. I have attached the > files. I have a Modbus front panel with a bunch of buttons. One (connected to > digital input 0) enables/disables auto tool set. Only tools 1-100 will auto > toolset. My probe is T101. Another button directly calls the tool set > subroutine so I can manually trigger a tool set. > > The probe and tool setter are in series so either will trigger the probe > input. Among other things this allows me to calibrate the probe relative to > the tool setter by simply doing a probe toolset. > > Les > >> On 13/11/2021 17:26, John Dammeyer wrote: >> Hi Les, >> I have to ask. How do you have an optional subroutine on M6? Can you share >> the code? >> Thanks >> John >> > <toolchange.ngc> > <toolset.ngc> > _______________________________________________ > Emc-users mailing list > [email protected] > https://lists.sourceforge.net/lists/listinfo/emc-users _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users