Is there a provision for tool setting a face mill or a tool with a different 
center height than the outside diameter?  Or do those have to be done manually? 
I imagine the spindle orientation would also matter for most tool setters due 
to the spacing of the inserts.  

Matthew Herd
[email protected]
610-608-8930

> On Nov 16, 2021, at 7:24 AM, Les Newell <[email protected]> wrote:
> 
> Sorry for the delay in replying. I missed your post. I have attached the 
> files. I have a Modbus front panel with a bunch of buttons. One (connected to 
> digital input 0) enables/disables auto tool set. Only tools 1-100 will auto 
> toolset. My probe is T101. Another button directly calls the tool set 
> subroutine so I can manually trigger a tool set.
> 
> The probe and tool setter are in series so either will trigger the probe 
> input. Among other things this allows me to calibrate the probe relative to 
> the tool setter by simply doing a probe toolset.
> 
> Les
> 
>> On 13/11/2021 17:26, John Dammeyer wrote:
>> Hi Les,
>> I have to ask.  How do you have an optional subroutine on M6?  Can you share 
>> the code?
>> Thanks
>> John
>> 
> <toolchange.ngc>
> <toolset.ngc>
> _______________________________________________
> Emc-users mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/emc-users


_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to