FWIW -- I've noticed this problem only after upgrading to 4.3 -- no troubles with prior versions. Flip to the Search Log tab while running a compass search and you can see just how slowly the data is being collected -- you can almost increment the numbers in your head. Disable redirection, and the numbers fly by in a blur.
Running on 2008R2 here, so I was going to try the vmware OVA to see if things improved there. In "copious spare time"... sounds like I may just want to open a ticket instead. Derek Johnson | Data Communications Coordinator FORT HAYS STATE UNIVERSITY 415 Lyman Dr. TH 101, Hays, KS 67601 (785) 628 - 5688 | [email protected] From: Markus Kaiser <[email protected]> To: "Enterasys Customer Mailing List" <[email protected]>, Date: 08/08/2012 03:22 PM Subject: Re: [enterasys] bug with Netsight 4.3.0.94 Sylvain, Did you had the problem before as well, I mean for example with versions 3.3, 4.0, 4.1, 4.2? Just asking because I've seen your name for many years I think on here in the newsgroup and I think you also have experience with a lot of netsight versions from the past. Or did the problems just started now with 4.3, like at Geoffrey? I have just very few customers which are using snmp redirection, but all with high latency WAN/VPN networks, where I thought it is normal. Thanks in advance. Kind regards, Markus ___________________________ On 08.08.2012, at 22:02, Sylvain Conti <[email protected]> wrote: Hi, In my lab. Server (virtual appliance) and remote desktop on the same vlan/ip network. A 24ports switch same vlan/ip network, flexview interface summary : - with redirection : 30secondes - without redirection : 2secondes Can you explain the difference with your formula ? At customer site with 30 chassis dfe with 5-7 boards it is unusable. Policy Manager is affected ... Regards, Cordialement, Sylvain CONTI. Retis Communication Coordinateur Technique Agence Ile de France 19bis av du Quebec - ZA Courtaboeuf 91140 Villebon-sur-Yvette +33164531412 / +33678780747 Mailto:[email protected] De : Kaiser, Markus [mailto:[email protected]] Envoyé : Wednesday, August 08, 2012 04:40 PM À : Enterasys Customer Mailing List <[email protected]> Objet : Re: [enterasys] bug with Netsight 4.3.0.94 Hello, how long is the round-trip time between you or the netsight server and the device? There are many snmp requests going on if you try to retrieve port information from a switch for many ports. Let's say 480 snmp requests for 10 stats about 48 ports. 480x 1ms = 480 ms to get the information from switches within a LAN. If your client is remote with a round-trip time of 120ms to netsight or netsight to device, that makes 480x 120ms = 57,6 seconds until information is retrieved. This is not a problem or issue of netsight. Hope this helps. Kind regards, Markus On Wed, Aug 8, 2012 at 3:07 PM, <[email protected]> wrote: Hello, We are testing the latest Netsight (4.3.0.94). When we enable the SNMP redirection, the display for ports or Vlan information of a switch is very long. When we disable the SNMP redirection, all is coming as usual. Has everyone seen the same problem ? Regards Geoffroy HUGUENIN CEA VALDUC VA/DSTA/STLI/LSIS 21120 IS-SUR-TILLE Téléphone : 03 80 23 77 80 --To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected] --To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected] --To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected] --To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected] --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected]