Hi 

With our lab, on N3 with 1 DFE Platinium 48 ports :

                Netsight 4.2 : with redirection – between 5 and 10 s

                                                    Without redirection – 15s

                Netsight 4.3 : with redirection – between 30 and 45 s

                                                    Without redirection – 15 s

 

We are testing the 4.3 on a production network with 52 switchs (1 N3, 1 N1, 2 
SSA, 48 G3) and with compass, it take between 3 and 5 minutes to retrieve an ip 
adress with the redirection and 1 minute without redirection. 

The 4.2 take 1 minute with and without redirection.

 

 

 

Geoffroy HUGUENIN

CEA VALDUC

VA/DSTA/STLI/LSIS

21120 IS-SUR-TILLE

Téléphone : 03 80 23 77 80

De : Sylvain Conti [mailto:[email protected]] 
Envoyé : jeudi 9 août 2012 09:23
À : Enterasys Customer Mailing List
Objet : Re: [enterasys] bug with Netsight 4.3.0.94

 

Hi,

The netsight latency with snmp redirection appeared with netsight 4.3.

All comparative tests do not show any problem with earlier versions, this is 
why some people are complaining about this new behaviour.

I have a case about this situation if you want to a look into this problem. 

Cordialement, 
Sylvain CONTI. 

Retis Communication 
Coordinateur Technique Agence Ile de France 
19bis av du Quebec - ZA Courtaboeuf 
91140 Villebon-sur-Yvette 
+33164531412 / +33678780747 
Mailto:[email protected]
 

De : Markus Kaiser [mailto:[email protected]] 
Envoyé : Wednesday, August 08, 2012 10:22 PM
À : Enterasys Customer Mailing List <[email protected]> 
Objet : Re: [enterasys] bug with Netsight 4.3.0.94 
 

Sylvain,

 

Did you had the problem before as well, I mean for example with versions 3.3, 
4.0, 4.1, 4.2? Just asking because I've seen your name for many years I think 
on here in the newsgroup and I think you also have experience with a lot of 
netsight versions from the past.

 

Or did the problems just started now with 4.3, like at Geoffrey?

 

I have just very few customers which are using snmp redirection, but all with 
high latency WAN/VPN networks, where I thought it is normal. 

 

 

Thanks in advance.

 

Kind regards,

 

Markus

 


___________________________


On 08.08.2012, at 22:02, Sylvain Conti <[email protected]> wrote:

        Hi,
        
        In my lab.
        
        Server (virtual appliance) and remote desktop on the same vlan/ip 
network.
        
        A 24ports switch same vlan/ip network, flexview interface summary :
        - with redirection : 30secondes
        - without redirection : 2secondes
        
        Can you explain the difference with your formula ?
        At customer site with 30 chassis dfe with 5-7 boards it is unusable. 
Policy Manager is affected ...
        
        Regards, 
        
        Cordialement, 
        Sylvain CONTI. 
        
        Retis Communication 
        Coordinateur Technique Agence Ile de France 
        19bis av du Quebec - ZA Courtaboeuf 
        91140 Villebon-sur-Yvette 
        +33164531412 / +33678780747 
        Mailto:[email protected]
         

        De : Kaiser, Markus [mailto:[email protected]] 
        Envoyé : Wednesday, August 08, 2012 04:40 PM
        À : Enterasys Customer Mailing List <[email protected]> 
        Objet : Re: [enterasys] bug with Netsight 4.3.0.94 
         

        Hello, 

         

        how long is the round-trip time between you or the netsight server and 
the device?

         

        There are many snmp requests going on if you try to retrieve port 
information from a switch for many ports.

         

        Let's say 480 snmp requests for 10 stats about 48 ports.

         

        480x 1ms = 480 ms to get the information from switches within a LAN.

         

        If your client is remote with a round-trip time of 120ms to netsight or 
netsight to device, that makes

         

        480x 120ms = 57,6 seconds until information is retrieved.

         

        This is not a problem or issue of netsight.

         

        Hope this helps.

         

         

        Kind regards,

         

        Markus

         

         

         

        On Wed, Aug 8, 2012 at 3:07 PM, <[email protected]> wrote:

        Hello,

         

        We are testing the latest Netsight (4.3.0.94). When we enable the SNMP 
redirection, the display for ports or Vlan information of a switch is very 
long. When we disable the SNMP redirection, all is coming as usual. 

         

        Has everyone seen the same problem ?

         

        Regards

         

        Geoffroy HUGUENIN

        CEA VALDUC

        VA/DSTA/STLI/LSIS

        21120 IS-SUR-TILLE

        Téléphone : 03 80 23 77 80

        *       --To unsubscribe from enterasys, send email to [email protected] 
with the body: unsubscribe enterasys [email protected] 

         

        *       --To unsubscribe from enterasys, send email to [email protected] 
with the body: unsubscribe enterasys [email protected] 

        *       --To unsubscribe from enterasys, send email to [email protected] 
with the body: unsubscribe enterasys [email protected] 

*       --To unsubscribe from enterasys, send email to [email protected] 
<mailto:[email protected]>  with the body: unsubscribe enterasys [email protected] 
<mailto:[email protected]>  

*       --To unsubscribe from enterasys, send email to [email protected] 
<mailto:[email protected]>  with the body: unsubscribe enterasys 
[email protected] <mailto:[email protected]>  


---
To unsubscribe from enterasys, send email to [email protected] with the body: 
unsubscribe enterasys [email protected]

Reply via email to