Hi, The netsight latency with snmp redirection appeared with netsight 4.3.
All comparative tests do not show any problem with earlier versions, this is why some people are complaining about this new behaviour. I have a case about this situation if you want to a look into this problem. Cordialement, Sylvain CONTI. Retis Communication Coordinateur Technique Agence Ile de France 19bis av du Quebec - ZA Courtaboeuf 91140 Villebon-sur-Yvette +33164531412 / +33678780747 Mailto:[email protected] De : Markus Kaiser [mailto:[email protected]] Envoyé : Wednesday, August 08, 2012 10:22 PM À : Enterasys Customer Mailing List <[email protected]> Objet : Re: [enterasys] bug with Netsight 4.3.0.94 Sylvain, Did you had the problem before as well, I mean for example with versions 3.3, 4.0, 4.1, 4.2? Just asking because I've seen your name for many years I think on here in the newsgroup and I think you also have experience with a lot of netsight versions from the past. Or did the problems just started now with 4.3, like at Geoffrey? I have just very few customers which are using snmp redirection, but all with high latency WAN/VPN networks, where I thought it is normal. Thanks in advance. Kind regards, Markus ___________________________ On 08.08.2012, at 22:02, Sylvain Conti <[email protected]<mailto:[email protected]>> wrote: Hi, In my lab. Server (virtual appliance) and remote desktop on the same vlan/ip network. A 24ports switch same vlan/ip network, flexview interface summary : - with redirection : 30secondes - without redirection : 2secondes Can you explain the difference with your formula ? At customer site with 30 chassis dfe with 5-7 boards it is unusable. Policy Manager is affected ... Regards, Cordialement, Sylvain CONTI. Retis Communication Coordinateur Technique Agence Ile de France 19bis av du Quebec - ZA Courtaboeuf 91140 Villebon-sur-Yvette +33164531412 / +33678780747 Mailto:[email protected] De : Kaiser, Markus [mailto:[email protected]<mailto:[email protected]>] Envoyé : Wednesday, August 08, 2012 04:40 PM À : Enterasys Customer Mailing List <[email protected]<mailto:[email protected]>> Objet : Re: [enterasys] bug with Netsight 4.3.0.94 Hello, how long is the round-trip time between you or the netsight server and the device? There are many snmp requests going on if you try to retrieve port information from a switch for many ports. Let's say 480 snmp requests for 10 stats about 48 ports. 480x 1ms = 480 ms to get the information from switches within a LAN. If your client is remote with a round-trip time of 120ms to netsight or netsight to device, that makes 480x 120ms = 57,6 seconds until information is retrieved. This is not a problem or issue of netsight. Hope this helps. Kind regards, Markus On Wed, Aug 8, 2012 at 3:07 PM, <[email protected]<mailto:[email protected]>> wrote: Hello, We are testing the latest Netsight (4.3.0.94). When we enable the SNMP redirection, the display for ports or Vlan information of a switch is very long. When we disable the SNMP redirection, all is coming as usual. Has everyone seen the same problem ? Regards Geoffroy HUGUENIN CEA VALDUC VA/DSTA/STLI/LSIS 21120 IS-SUR-TILLE Téléphone : 03 80 23 77 80 * --To unsubscribe from enterasys, send email to [email protected]<mailto:[email protected]> with the body: unsubscribe enterasys [email protected]<mailto:[email protected]> * --To unsubscribe from enterasys, send email to [email protected]<mailto:[email protected]> with the body: unsubscribe enterasys [email protected]<mailto:[email protected]> * --To unsubscribe from enterasys, send email to [email protected]<mailto:[email protected]> with the body: unsubscribe enterasys [email protected]<mailto:[email protected]> * --To unsubscribe from enterasys, send email to [email protected]<mailto:[email protected]> with the body: unsubscribe enterasys [email protected] --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected]