OTS, McMaster-Carr, page 252 in the on-line catalog.  I now recall that the
PVDF pumps were the ideal, but we cheaped out and used the Polypropylene
w/Teflon diaphragm unit; probably 4157K89 in the current catalog.  They
worked great, never a problem.  However, don't let the HTP sit in a
Polypropylene pump; flush with distilled water and air after use with HTP,
and always leave a filtered air vent open on the outlet.  Any decomposing
residual HTP could overpressure it if stored with closed valves.  The PVDF
w/teflon unit is more compatible if you have the budget.
Ken

----- Original Message -----
From: Alex Fraser
To: [EMAIL PROTECTED]
Sent: Saturday, June 22, 2002 7:14 AM
Subject: Re: [ERPS] A Rocket A Day



OTS or scratch built?
Ken Doyle wrote:
John,  I mounted air-powered diaphragm pumps on each trailer, above the tank
top level and plumbed for full drainage and purge capability.  The pumps
were made from PVDF, as I recall.
--
>>>>>>>>>>>>>>>>----<<<<<<<<<<<<<<<<<
........ Alex Fraser  N3DER .........
......... [EMAIL PROTECTED] .......
[~]_>^</\-[~]_>^</\-[~]_>^</\-[~]_>^<


_______________________________________________
ERPS-list mailing list
[EMAIL PROTECTED]
http://lists.erps.org/mailman/listinfo/erps-list

Reply via email to