Mischa is correct - you can define up to 64 IPs which is a hard limit. I am sorry for that.

R, Oliver

At 21:21 13.11.2008, Mischa Peters wrote:
Hi Stephan,

The amount of virtual interfaces is also (unfortunately) limited by
the 64 IP limit.
This is a combined limit for both source-ips and VEs.

Mischa

Hmms didn't think I would hit the serveriron's limit that soon... :(
But how is this related to the maximum ammount of virtual-interface
then ? (which can be 512)

So no other options than just buying another pair of foundry's ?
(not sure if I need to buy serverirons, since i would be able to
move ve's which don't use loadbalancing)

Thnx,

Stephan



On Thu, 13 Nov 2008, Mischa Peters wrote:

You can not change that limit, that is a hard limit on the BPs of
the ServerIron.

Mischa

When I tried to create another vlan with ve I got the following
message :
Error! Maximum number of IP reached 64
In the past I also had a maximum vlan, which I could fix by using
system-max vlan.
But I can't find anything about this ip limit in the documentation/ specs.
Any hints how to fix this ?