That's a good idea, didn't know about the VLL architecture, but I would need a 
better backbone/mesh to do that, and I really don't have that "hub" point.





>________________________________
> From: Mark Tees <[email protected]>
>To: Youssef Bengelloun-Zahr <[email protected]> 
>Cc: Eric Louie <[email protected]>; foundry-nsp <[email protected]> 
>Sent: Wednesday, August 28, 2013 6:43 PM
>Subject: Re: [f-nsp] NetIron CER 2000 as a metro switch
> 
>
>
>If you want to do L3/PE services for customers and want to keep costs down it 
>might be feasible to use CES at access points then ship traffic using VLL's to 
>a couple of strategically placed PE L3 devices that could be CER or larger?
>
>
>
>On Thu, Aug 29, 2013 at 9:28 AM, Youssef Bengelloun-Zahr <[email protected]> 
>wrote:
>
>Hello,
>>
>>
>>I would advise you to take a close look to the data sheets for both product 
>>lines with your SE.
>>
>>
>>My personal opinion, I'd get a CER because it can pretty much do anything a 
>>CES does and much more if needed in a later futur. But that's me ;-)
>>
>>
>>Hope this helps.
>>
>>
>>Y.
>>
>>
>>
>>
>>Le 29 août 2013 à 01:16, "Eric Louie" <[email protected]> a écrit :
>>
>>
>>Ok
>>> 
>>>It’s being used as a base switch.  Each GigE port may be servicing up to 10 
>>>customers over a trunked interface, though port bandwidth utilization will 
>>>rarely exceed 150 Mbps.  Most of those connections will be simple 
>>>point-to-point IP connections via individual VLANs.  24 ports is the most 
>>>we’ll need at any site, and the switches are interconnected via backhaul WAN 
>>>circuits to form a ring or partial mesh as the backhaul topology allows.  IP 
>>>is routed within the backbone using OSPF.  We have a combination of public 
>>>(customer assigned) and private (internal use) IP addresses within the 
>>>backbone.
>>> 
>>>Part of our growth path will be to offer MPLS via VRF circuits between 
>>>switches, regionally and locally.  Customers with multiple locations in our 
>>>regional area will have the ability to interconnect their offices using 
>>>VRFs.  We will also offer IPv6 to our customers as these new switches are 
>>>installed.  
>>> 
>>>much appreciated,
>>>Eric Louie
>>> 
>>>From:Youssef Bengelloun-Zahr [mailto:[email protected]] 
>>>Sent: Wednesday, August 28, 2013 4:01 PM
>>>To: Eric Louie
>>>Cc: foundry-nsp
>>>Subject: Re: [f-nsp] NetIron CER 2000 as a metro switch
>>> 
>>>Well,
>>> 
>>>First of all, one is a switch who can do a little routing with small RIB 
>>>capacity while the other is a router who can do a little switching whit high 
>>>RIB capacity.
>>> 
>>>Again, if you don't state your needs/requirements/sizing, it's going to be 
>>>difficult to help.
>>> 
>>>Y.
>>>
>>>
>>>
>>>Le 29 août 2013 à 00:54, "Eric Louie" <[email protected]> a écrit :
>>>What’s the difference between the CER and the CES?  From the local Systems 
>>>Engineer, he says “L3 VPNs on the CER, L2 VPNs on the CES”.  Any other 
>>>notable differences?
>>>> 
>>>>much appreciated,
>>>>Eric Louie
>>>> 
>>>>From:Youssef Bengelloun-Zahr [mailto:[email protected]] 
>>>>Sent: Wednesday, August 28, 2013 3:45 PM
>>>>To: Eric Louie
>>>>Cc: foundry-nsp
>>>>Subject: Re: [f-nsp] NetIron CER 2000 as a metro switch
>>>> 
>>>>Hello Eric,
>>>> 
>>>>I have been running CER-RT as route reflectors and MPLS PEs for our "small" 
>>>>POPs just fine.
>>>> 
>>>>Now, if you are looking for metro switchs as a replacement for Cisco 
>>>>ME3600, you should probably take a look at the CES switchs destined for 
>>>>that typical use case.
>>>> 
>>>>Again, it all depends on your requirements/needs/sizing which you didn't 
>>>>specify.
>>>> 
>>>>HTH.
>>>> 
>>>>
>>>>Le 29 août 2013 à 00:31, "Eric Louie" <[email protected]> a écrit :
>>>>I’m considering using the CER 2000 as a mpls PE switch.  I have been told 
>>>>that the CER-RT can also be used as an Internet edge switch (will hold 
>>>>multiple BGP tables)
>>>>> 
>>>>>I’m interested in your experiences in configuration and operation in 
>>>>>either application.  What are you using for CE devices?  (Brocade doesn’t 
>>>>>seem to have a branch office router)
>>>>> 
>>>>>(Currently using Cisco ME3600-X for PE and c871 for CE)
>>>>> 
>>>>>much appreciated,
>>>>>Eric Louie
>>>>> 
>>>>_______________________________________________
>>>>>foundry-nsp mailing list
>>>>>[email protected]
>>>>>http://puck.nether.net/mailman/listinfo/foundry-nsp
>>_______________________________________________
>>foundry-nsp mailing list
>>[email protected]
>>http://puck.nether.net/mailman/listinfo/foundry-nsp
>>
>
>
>
>-- 
>Regards,
>
>Mark L. Tees
>
>
>
_______________________________________________
foundry-nsp mailing list
[email protected]
http://puck.nether.net/mailman/listinfo/foundry-nsp

Reply via email to