It is is really bright there, try putting a few control points in WM 
(make sure they are in WM)

On 3/3/20 12:30 PM, Laboratorio de Neurociencia Funcional wrote:
>
>         External Email - Use Caution
>
> Dear Freesurfeer experts,
> After running the recon-all in one of my subjets, part of the temporal lobe 
> was partially excluded. Then, I tried to use the watershed algorithm to be 
> less agressive in the skull stripping
> as follows:
>
> recon-all -skullstrip -wsthresh 35 -clean-bm -no-wsgcaatlas -subjid sub_001
>
> The problem was solved in the brainmask.mgz but not in the cortical surfaces. 
> To
> handle this issue, I edited the white matter and run the recon-all 
> -autorecon2-wm
> -autorecon3 without success. I also placed control points but the following 
> error appeared after running
> the recon-all -autorecon2-cp -autorecon3:
>
> recon-all -s sub_001 existed with errors
>
> I noted that white matter of this part of the temporal lobe has high values 
> (up to 132). What can I
> do to solve the problem with this subject?
>
> Thank you in advance.
>
> Best regards,
> Marina
>
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

Reply via email to