Colin D Bennett <[email protected]> writes: > Sometimes I would like to directly connect two nets. There are a > number of different specific cases in which I would like to do this for > simplicity in the schematic. For instance, I might have an "input port" > component (e.g., input-1.sym) on a connector pin with net "VLCD", and > then somewhere else in the schematic want to show that "VLCD" is > connected to "+3.3V". > > However, after some investigation as to why I wasn't getting the right > rats in 'pcb' after a gsch2pcb import, I realized that connecting two > nets in gschem (using a power symbol and/or an I/O port symbol > connected with a net line) does not create that connection in the > netlist! I think the gnetlist drc did emit a warning due to this, but > I did not understand the cause... > > Is there any correct way to show two nets are directly connected in a > schematic? e.g., connecting two I/O ports or two power symbols > directly.
Hmm, yes. You need to invent some 2-pin symbol with some special attributes, and teach the pcb gnetlist backend(s) to interpret those attributes as a net-unification bridge. There should also be a convention how that net should be named in the output. -- Stephan _______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user