Hi! I am not a developer of Gerbv. But what you want needs more background information than just the plain gerber data from the files to determine whether elements are electrically connected or not.
You need to check the drill data as well (plated/non-plated). The Layer Stackup needs to be known to Gerbv. But once all the data is there, you could work your way throught the Layer Stack with some Logic. Example: when you have Copper on Layer 1 AND a plated drill on the layer in between L1 and L2 AND Copper on Layer L2 then the elements are connected (somehow). Regards, Clemens -- Embeon SDE Muenchen --- On 10/29/2014 06:29 PM, Valerio Messina wrote: > hi, > I opened a RFE: > https://sourceforge.net/p/gerbv/feature-requests/69/ > to let select tracks across different layers. > What I can do to help on this? > > Valerio > > > > > ------------------------------------------------------------------------------ > > > > _______________________________________________ > Gerbv-devel mailing list > Gerbv-devel@lists.sourceforge.net > https://lists.sourceforge.net/lists/listinfo/gerbv-devel > ------------------------------------------------------------------------------ _______________________________________________ Gerbv-devel mailing list Gerbv-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/gerbv-devel