On Wed, 11 Mar 2009, [email protected] wrote: > refill, > maybe to get a best value between distortion ( non tangential connection from > last frame at beginning from > linear-interpolation ) and fast release is to define the min-release lenght > for 1 0to0 (180 degree) time from the lowest usable audiofrequenz. e.g. 25Hz. > = 1/50 sec. > than the current zero-offset frames must computed and rounded up for each > used samplerate. >
A quick google shows that typical synths will provide a minimum release time that is 1 ms to 2.5 ms (typically 40 to 120 frames). However, KF's 20 ms suggestion sounds reasonable to me. Since the sampler is doing this based on frames and not seconds... why not test with a number around 120 frames and see how it sounds. -gabriel ------------------------------------------------------------------------------ Apps built with the Adobe(R) Flex(R) framework and Flex Builder(TM) are powering Web 2.0 with engaging, cross-platform capabilities. Quickly and easily build your RIAs with Flex Builder, the Eclipse(TM)based development software that enables intelligent coding and step-through debugging. Download the free 60 day trial. http://p.sf.net/sfu/www-adobe-com _______________________________________________ Hydrogen-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/hydrogen-devel