Ottar Moller wrote:
Hi there,
I was adding a new CHP to a device and reused an old CHP. I can't get the
new CHP working and when I list the CHP (d m=chp(B8)) I get:
CHPID B8: TYPE=04, DESC=ESCON SWITCHED OR POINT TO POINT, ONLINE
When looking at the other CHPs for the same device I get:
CHPID B0: TYPE=03, DESC=ESCON POINT TO POINT, ONLINE
They are both defined as CNC and I can't find out where to change TYPE=04 to
TYPE=03.
Any hints?
Best regards,
Ottar
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
Ottar,
Is the new CHP connected to switch/port?
To find out, start HCD,option 1, option 3, S on the config name, V on
the CHP. Look at the Switch, Port info.
Salah
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html