Patrich,

that can work provided thet you have defined and initialized a new XCF
couple dataset and a DR copy
of your COUPLExx member of PARMLIB, pointing to this XCF CDS and containing
the CFRMPOL
parameter, related to the CDRM policy name you want to start at the DR
site. In this case, your
policy can contain both primary and DR CFs.

Hope this helps

snip....

We are in the process of setting up a new Disaster Recovery scenario
using PPRC DASD and a Hot Stand-by datacenter (z9 CBU processor)

I have a question concerning how others have dealt with using a Coupling
Facility in this scenario. At our DR site we will have one ICF
configured on the same processor our z/OS image will run on .... no
problem so far.

We would like to not maintain multiple CF policies, all Structures at
our primary location will need to be created at the Disaster site. If
the COUPLE Datasets are Mirrored, how can I IPL the DR machine when the
CFs will be different?

Can I code a CF policy that has the DR CF defined as a non-preferred CF
during normal processing and when a DR is called, will the Mirrored z/OS
IPL and fail trying to use the primary CF and failover to the DR CF?


Policy example:

CF NAME(CF01)                     <==== normal CF
       ..
       ..
       DUMPSPACE(2000)

CF NAME(CF02)                     <===== normal CF
       ..
       ..
       DUMPSPACE(2000)

 CF NAME(CFCBU)                   <====== DR CF
       ..
       ..
       DUMPSPACE(2000)

STRUCTURE NAME(OPERLOG_STRUCT)
          PREFLIST(CF01,CF02,CFCBU)

Would this work if CF01 and CF02 are the "normal" CFs in use and CFCBU
CF would only be used if IPL'd at he DR location?

I rambled a bit, just couldn't figure a way to explain this easily.


_________________________________________________________________________
Paolo Cacciari
Business Continuity and Recovery Services, IBM Global Services - South
Region, EMEA
Via Darwin 85, 20019 Settimo Milanese(MI) – Italy - MISET001
"The goal is to be prepared for a disaster not to continually plan for a
successful test"
* [EMAIL PROTECTED]
( + 39 051 41.36799   Mobile: + 39 335 6287584
7 + 39 02 596.23288

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to