> -----Original Message-----
> From: IBM Mainframe Discussion List On Behalf Of McKown, John
>
> [ snip ]
>
> As others have said, I'd create a new IEASYSnn member in
> PARMLIB with my new paging configuration. I've finger checked
> too many times to trust myself anymore. Refer to the new
> IEASYSnn member in a new LOADnn member of SYS1.IPLPARM. When
> you IPL, point to the new LOADnn member. That way, if
> anything goes wrong, you should still be able to IPL with the
> old configuration. Paranoid? You bet!
That's not paranoia; that's acceptance of "Murphy's Law" as one of the
immutable laws of the universe.
-jc-
----------------------------------------------------------------------