Hello Howard,

Multiple OS Configuration can be handled by multiple LOAD members.

My OS/Configuration lists look like this:

/ Config. ID   Type     Description                     
_ COB          MVS      C.o.B. Real Configuration       
_ COBDRILL     MVS      C.o.B. Drill Configuration      
_ DVLPMENT     MVS      Development Configuration       
_ OTHER        MVS      Alternative Configuration       
_ PROD         MVS      Production Configuration        
_ SYSMAINT     MVS      System Maintenance Configuration
******************************* Bottom of data *********

The required LOAD member parameter is:
*---+----1----+----2----+----3----+----4----+----5----+----6----+----7-- 
IODF     -- HCD      SYSMAINT 88 Y   
IODF     -- HCD      PROD     88 Y  
IODF     -- HCD      DVLPMENT 88 Y      

Starting in column 22 is the name of the required OS Configuration.
column 31 is the EDT number....your OS Configuration must contain this EDT.

Regards
Bruce Hewson

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html