Good Day,
I encountered the following error while I was attempting to define the VVDS
on a 3390-9 disk which is SMS managed:
IDC3014I CATALOG ERROR
IDC3009I ** VSAM CATALOG RETURN CODE IS 50 - REASON CODE IS IGG0CLE3-8
IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12
I checked the error code and it points out to the fact that "a VVDS already
exists on the volume"
I am not sure how that can happen because I initialized the volume (ICKDSF)
and put it online and attempted to define the VVDS. Can it be because as soon
as I put the volume online a VSAM file may have been allocated on that volume?
If so, how can I avoid this problem in the future.
Here is my init job
INIT -
UNITADDRESS(BC50)
VOLID(PAS904) -
VTOC(0,1,149) -
VERIFY(SPAC50) -
INDEX(10,0,45) -
STORAGEGROUP
Thanks.
---------------------------------
Stay in the know. Pulse on the new Yahoo.com. Check it out.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html