Add the DEFINE of the VVDS as the 2nd step of your INIT jcl.

Bob Richards 



-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of willie bunter
Sent: Monday, September 18, 2006 8:14 AM
To: [email protected]
Subject: CATALOG ERROR - Defining VVDS

Good Day,
   
  I encountered the following error while I was attempting to define the
VVDS on a 3390-9 disk which is SMS managed:
   
  IDC3014I CATALOG ERROR

IDC3009I ** VSAM CATALOG RETURN CODE IS 50 - REASON CODE IS IGG0CLE3-8 
IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12                     

  I checked the error code and it points out to the fact that "a VVDS
already exists on the volume"
   
  I am not sure how that can happen because I initialized the volume
(ICKDSF) and put it online and attempted to define the VVDS.  Can it be
because as soon as I put the volume online a VSAM file may have been
allocated on that volume?  If so, how can I avoid this problem in the
future.  
   
  Here is my init job
   
  INIT -                
     UNITADDRESS(BC50)
     VOLID(PAS904) -  
     VTOC(0,1,149) -  
     VERIFY(SPAC50) - 
     INDEX(10,0,45) - 
     STORAGEGROUP 
  
  
  
LEGAL DISCLAIMER 
The information transmitted is intended solely for the individual or entity to 
which it is addressed and may contain confidential and/or privileged material. 
Any review, retransmission, dissemination or other use of or taking action in 
reliance upon this information by persons or entities other than the intended 
recipient is prohibited. If you have received this email in error please 
contact the sender and delete the material from any computer. 
  
Seeing Beyond Money is a service mark of SunTrust Banks, Inc. 
[ST:XCL] 
 
 
 
 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to