Hello Jon,

1. add enough SMF datasets to cover your longest enqueue time...

e.g.

  NAME                VOLSER SIZE(BLKS) %FULL  STATUS               
P-SYS1.SYSA.SMFDS1    PRDSM1    100020   100  DUMP REQUIRED         
S-SYS1.SYSA.SMFDS2    PRDSM2    100020     8  ACTIVE                
S-SYS1.SYSA.SMFDS3    PRDSM3    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDS4    PRDSM4    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDS5    PRDSM5    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDS6    PRDSM6    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDS7    PRDSM7    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDS8    PRDSM8    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDS9    PRDSM9    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDSA    PRDSM9    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDSB    PRDSM9     90000     0  ALTERNATE             
S-SYS1.SYSA.SMFDSC    PRDSMA    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDSD    PRDSMA    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDSE    PRDSMA     90000     0  ALTERNATE             
S-SYS1.SYSA.SMFDSF    PRDSMB    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDSG    PRDSMB    100020     0  ALTERNATE             
S-SYS1.SYSA.SMFDSH    PRDSMB     90000     0  ALTERNATE             

We are putting 3 50,000 track datasets on a mod-9.

so far today we have DUMPed to 18 times for the two members of the sysplex.

SMF.DUMP.G0001V00   
SMF.DUMP.G0002V00   
SMF.DUMP.G0003V00   
SMF.DUMP.G0004V00   
SMF.DUMP.G0005V00   
SMF.DUMP.G0006V00   
SMF.DUMP.G0007V00   
SMF.DUMP.G0008V00   
SMF.DUMP.G0009V00   
SMF.DUMP.G0010V00   
SMF.DUMP.G0011V00   
SMF.DUMP.G0012V00   
SMF.DUMP.G0013V00   
SMF.DUMP.G0014V00   
SMF.DUMP.G0015V00   
SMF.DUMP.G0016V00   
SMF.DUMP.G0017V00   
SMF.DUMP.G0018V00   

2. I have in the pipeline a process which uses date-time stamped datasets 
instead of GDG datasets. This removes the GDG enqueues.

Written in REXX....there is also a second REXX to handle the MXG portion of 
the process. sorry I cant release them.... but you have the idea.

Regards
Bruce Hewson

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to