Barry -  I've heard from a couple of other on the list 'off-list' and it 
appears that this is a known issue with EOS & I'll have to keep some 
mod-3's around to use with this product. 
thanks - dkk





"Schwarz, Barry A" <[EMAIL PROTECTED]> 
Sent by: IBM Mainframe Discussion List <[email protected]>
04/25/2008 02:12 PM
Please respond to
IBM Mainframe Discussion List <[email protected]>


To
[email protected]
cc

Subject
Re: EOS & Mod-27's






It sounds like EOS is having trouble with a device value (such as
cylinder or number of tracks) being "too large".  When the index files
are allocated, do they go near the front of the volume (low cylinder
numbers)?  Is the data the index files "point to" also allocated on low
cylinders?  When EOS runs, are any of its datasets, including temporary
ones, allocated near the back of the volumes?






**************************************************************************************