On Tue, 6 May 2008 13:37:40 -0700, John Mattson wrote:

>        I am still running 3174's connected by adaptors to Escon channels
>for my MVS consoles.  Not elegant, but it works.  For normal production
>work, I want all of the IPL, and other messages to go to the attached
>consoles because that is what the operators are used to.  But for testing
>I would like to see all of this going to the HMC's "Operating System
>Messages".  I have found that by leaving the consoles out of the IODF
>using the "Operating System configuration" "Consoles", that I can
>accomplish getting the messages to the HMC.  Is there an easier way to
>switch between where the messages, especially the early IPL messages go?
>

What if you physically powered off the console devices that are defined in the 
IODF?  If none of the devices defined in the IODF are available at IPL, then 
z/OS will send NIP-time messages to the HMC console.

The power switch is a pretty simple "switch", one which is dynamic and easy 
to implement and back out!

Brian

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html