Eric, Don't know what happened to my first reply so will try again.
When you do a flash copy the target unit is invalidated so that it cannot be brought online. FDR supplies a utility to restore it to the original source volser if you really want to. First to flash the volume to an offline volume //FLASH EXEC PGM=FDRABR,REGION=0M,COND=(0,NE) //TAPE1 DD DUMMY,LABEL=RETPD=15 //TAPE2 DD DUMMY,LABEL=RETPD=15 //SYSPRIN1 DD SYSOUT=* //SYSPRIN2 DD SYSOUT=* //SYSPRINT DD SYSOUT=* //SYSUDUMP DD SYSOUT=* FCOPY TYPE=FDR,VERIFYVOLSER=NO,CONFMESS=NO MOUNT VOL=DB2E49,FLASHUNIT=628B /* The to back up the flashed volume to tape //STEP010 EXEC PGM=FDRABR //SYSPRINT DD SYSOUT=* //SYSPRIN1 DD SYSOUT=* //SYSPRIN2 DD SYSOUT=* //ABRMAP DD SYSOUT=* //SYSUDUMP DD SYSOUT=R,HOLD=YES //TAPE1 DD DSN=FDRABR.PROD.DBE1001, // DISP=(NEW,KEEP), // UNIT=MAGTAPE, // VOL=(,,,50) //SYSIN DD * DUMP TYPE=FDR,DSNENQ=NONE,PRINT=ABR,BUFNO=MAX,RTC=YES, ENQERR=NO,TAPERRCD=NO,SELTERR=NO,RTC=YES,FCOPY=(USE,REL) MOUNT VOL=DB2E* /* FDR also invokes flash copy when use use FDRCOPY to copy a data set. Really fast! Jerry ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html