On Thu, 18 Dec 2008 09:27:08 -0500, Dave Quinton
<[email protected]> wrote:

>You could place the START commands for the STCs at the end of the JES2 startup
>parms, as $VS commands.
>

I've done this and a combination of an IEBEDIT STC to submit JOB(s) to the
INTRDR in the past.   

If you don't want a "pure z/OS" solution, I've been using the COMMAND
package from file 19 of the CBT collection (http://www.cbttape.org) for
years in my sandbox LPARs to automate the IPL and shutdown.  It has 
must less overhead than running our AO software... and the sysprogs
have control over it. :-)    At IPL time I just have an entry in COMMNDxx
of "S STARTSYS" - which is a STC executes COMMAND and for shutdown
I use "S SHUTSYS,SUB=MSTR" which shuts everything down and even
issues the "V XCF,sysname,OFFLINE".

BTW, you're not the first to ask for suggestions.  Search the archives.

Mark
--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group - ZFUS G-ITO
mailto:[email protected]
z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html