On Thu, 18 Dec 2008 13:52:03 -0600, SUBSCRIBE IBM-MAIN M. Ioia
<[email protected]> wrote:

>Hey Scott, nothing special here.  We just have a started task that abends
>during IPL because it seems to be conflicting with JES startup.  It works
fine if
>we delay the startup until JES has completed its startup.  For automation
>purposes, I want to start this STC during COMMNDxx processing, but ensure
>that JES has finished its start up process.
>
>So that is why I went into a hunt for a solution to trigger something only
after
>JES has started.
>

Is this something that is started with SUB=MSTR?  Does the STC name match a 
defined subsystem?  Otherwise it should be in "STARTING" status until
JES2 is initialized without doing anything special.  

--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group - ZFUS G-ITO
mailto:[email protected]
z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/