So -
1) IOSAS is setup correctly
2) IOSAS starts well before TSS comes up in the IPL
3) After an IPL the encryption job is run it gets
a) An I/O Error with IOS628E error message
b) Then successfully (without stopping) mounts and encrypts a tape
c) All encryption jobs are now successful
4) This chews up my native tapes since I have so few.
5) I have two EKMSERV running at all times. This did not alleviate the
problem.
Questions:
1) Where or how should TSS be started at IPL time. Is it the first think up
or can it start after JES2?
2) Do you use generic users for IOSAS and OMVS?
CA feels starting TSS before JES2 could help. Yet, I am not sure I see how
that could be better.
"The IOS628E is a result of how the first security call is processed once TSS
is up for an address space that is started before TSS.
There are times when this first call may fail and this has to do with the way
we convert the address space (started before TSS) to use security, particularly
with OMVS. In these circumstances, it is only the first call that fails. After
that, anytime the process is done it should work without having to do anything
else."
Any other thoughts? I really hate to have to fix tapes all the time because it
fails. And it is most of the time not periodically.
Lizette
>The actual error message is
>
>IOS628E ENCRYPTION ON DEVICE 0A0D HAS FAILED DUE TO OMVS SEGMENT
>FAILURE FOR IOSAS
>
>However, once the tape is dropped with the I/O error, the next tape mounted
>runs successfully. The job runs to good eoj.
>
>Lizette
>
>
>
>>
>>Yes, we are a TSS shop using EKM. However, we don’t do any native tape
>>encryption. All of ours is behind a TS7700 VTS. Sounds likely, however,
>>what CA is telling you. My suggestion to you is to have more than one EKM
>>Server, so that at least one is up all the time. If you only run a single
>>production LPAR, then I guess that is a problem. If you have a development
>>LPAR, I would consider running EKM there as well.
>>
>>Didn’t CA tell you exactly what is wrong with the ACID? What is the
>>additional message text of IOS638E. There appears to be multiple scenarios
>>this message documents.
>>
>>
>
>>
>>I am having an issue with IOSAS and TSS. After an IPL the first job that
>>requests an encryption of a tape fails with IOS628E. This causes my tape to
>>have an I/O error and is dismounted. The job then immediately mounts a new
>>tape and viola it runs to a good EOJ. However, now I have a tape I have to
>>correct in CA1 and ISMF in order to use it again.
>>
>>IBM sent me to CA and CA TSS is saying this is due to TSS coming up later
>>than IOSAS and the ACID is not quiet correct.
>>
>>Anyone else run into this?
>>
>>Lizette
>>
>>PS Sorry if this is a duplicate.
>>
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html