Just another thought, may or may not fix this problem. But what if you setup 
IECIOSxx to EKM NONE, then once up, issue a SETIOS EKM command?

_________________________________________________________________
Dave Jousma
Assistant Vice President, Mainframe Services
[email protected]
1830 East Paris, Grand Rapids, MI  49546 MD RSCB1G
p 616.653.8429
f 616.653.8497


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of 
Lizette Koehler
Sent: Monday, February 02, 2009 1:47 PM
To: [email protected]
Subject: Re: Top Secret and EKM

So - 

1)  IOSAS is setup correctly
2)  IOSAS starts well before TSS comes up in the IPL
3)  After an IPL the encryption job is run it gets
    a)  An I/O Error with IOS628E error message
    b)  Then successfully (without stopping) mounts and encrypts a tape
    c)  All encryption jobs are now successful
4)  This chews up my native tapes since I have so few.
5)  I have two EKMSERV running at all times.  This did not alleviate the 
problem.

Questions:
1)  Where or how should TSS be started at IPL time.  Is it the first think up 
or can it start after JES2?
2)  Do you use generic users for IOSAS and OMVS?

CA feels starting TSS before JES2 could help.  Yet, I am not sure I see how 
that could be better.

"The IOS628E is a result of how the first security call is processed once TSS 
is up for an address space that is started before TSS.
There are times when this first call may fail and this has to do with the way 
we convert the address space (started before TSS) to use security, particularly 
with OMVS. In these circumstances, it is only the first call that fails. After 
that, anytime the process is done it should work without having to do anything 
else."

Any other thoughts?  I really hate to have to fix tapes all the time because it 
fails.  And it is most of the time not periodically.


Lizette


>The actual error message is
>
>IOS628E ENCRYPTION ON DEVICE 0A0D HAS FAILED DUE TO OMVS SEGMENT   
>FAILURE FOR IOSAS                                                  
>
>However, once the tape is dropped with the I/O error, the next tape mounted 
>runs successfully.  The job runs to good eoj.
>
>Lizette
>
>
>
>>
>>Yes, we are a TSS shop using EKM.  However, we don’t do any native tape 
>>encryption.  All of ours is behind a TS7700 VTS.  Sounds likely, however, 
>>what CA is telling you.  My suggestion to you is to have more than one EKM 
>>Server, so that at least one is up all the time.  If you only run a single 
>>production LPAR, then I guess that is a problem.  If you have a development 
>>LPAR, I would consider running EKM there as well.
>>
>>Didn’t CA tell you exactly what is wrong with the ACID?  What is the 
>>additional message text of IOS638E.  There appears to be multiple scenarios 
>>this message documents.
>>
>>
>
>>
>>I am having an issue with IOSAS and TSS.  After an IPL the first job that 
>>requests an encryption of a tape fails with IOS628E.  This causes my tape to 
>>have an I/O error and is dismounted.  The job then immediately mounts a new 
>>tape and viola it runs to a good EOJ.  However, now I have a tape I have to 
>>correct in CA1 and ISMF in order to use it again.
>>
>>IBM sent me to CA and CA TSS is saying this is due to TSS coming up later 
>>than IOSAS and the ACID is not quiet correct.
>>
>>Anyone else run into this?
>>
>>Lizette
>>
>>PS Sorry if this is a duplicate.  
>>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

This e-mail transmission contains information that is confidential and may be 
privileged.   It is intended only for the addressee(s) named above. If you 
receive this e-mail in error, please do not read, copy or disseminate it in any 
manner. If you are not the intended recipient, any disclosure, copying, 
distribution or use of the contents of this information is prohibited. Please 
reply to the message immediately by informing the sender that the message was 
misdirected. After replying, please erase it from your computer system. Your 
assistance in correcting this error is appreciated.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to