That is incorrect. Recycle does not finish the tape when the Hold command is 
issued. Recycle finishes the dataset that is in progress and then comes to 
pre-mature end.
A Hold on Expirebv has the same effect.

VOLSER    UNIT    VOL      REUSE     VALID   PCT    VOL    RACF  PREV    SUCC  
          NAME    TYPE   CAPACITY    BLKS    VALID  STATUS       VOL     VOL   
H00064    3490   SPILL 0003606100 0002280558 064    FULL    NO   *NONE*  H00179
H00179    3490   SPILL 0003606100 0001277632 036    FULL    NO   H00064  *NONE*

Issue Recycle against volume H00064 at 8:32
Hold Recycle issued at 8:51

08.51.02 STC21688  ARC0833I RECYCLE ENDED ON VOLUME H00064, 0000380 DATA     
               ARC0833I (CONT.) SETS MOVED, TIME 08:51:02, RC=0012, REAS=000

ARC0835I RECYCLE PROCESSING TERMINATING EARLY, RC=0012, REAS=0000          
ARC0831I RECYCLE COMMAND PROCESSING ENDING                                 
ARC1001I RECYCLE EXECUTE VOLUME(H00064) COMMAND FAILED, RC=0010, REAS=0016
ARC1610I LONG RUNNING COMMAND DID NOT FULLY COMPLETE   

List TTOC shows a reduced Pct Valid after Recycle command.

VOLSER    UNIT    VOL      REUSE     VALID   PCT    VOL    RACF  PREV    SUCC  
          NAME    TYPE   CAPACITY    BLKS    VALID  STATUS       VOL     VOL   
H00064    3490   SPILL 0003606100 0002075223 058    FULL    NO   *NONE*  H00179
H00179    3490   SPILL 0003606100 0001277632 036    FULL    NO   H00064  *NONE*
***END OF CONNECTED TAPE VOLUME SET ***                                        

Dave O'Brien
NIH Contractor
________________________________________
From: IBM Mainframe Discussion List [[email protected]] On Behalf Of L D 
Owen [[email protected]]
Sent: Tuesday, March 10, 2009 3:58 PM
To: [email protected]
Subject: Re: DFHSM Issue - Critical

I agree with "don't cancel" as many bad things can and do happen.

When you hold RECYCLE, it will finish the tape it is currently recycling, and if
I'm not wrong, it will finish the entire volume chain (if the volume was part of
a chain).  Try HOLD RECYCLE EOD instead as it will hold at the end of the
current dataset.

Audit is another long-running function that can also hold up CDS Backups.  I'm
not sure if HOLD AUDIT EOD helps, but I generally add EOD to everything just
to be sure.

Yes, CDS backups are the first thing AUTOBACKUP does...SSM does not kick
off any CDS bkups.

...LDO

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html