In
<CAFMxNW+NmuenEh0Tem8RnQdZ=jtgauuhsoilq6iussgrltr...@mail.gmail.com>,
on 08/07/2012
at 12:03 PM, Sam Siegel <[email protected]> said:
>An 0c7 is a data exception error detected by the hardware.
No; it is an ABEND detected by the Program FLIH when there is no SPIE
to catch interupt code 7.
>Without examining the data and software, it is not possible to make
>a definitive statement regarding the cause of the error.
Wrong; the cause of the error is treating data as decimal without
validating them.
--
Shmuel (Seymour J.) Metz, SysProg and JOAT
ISO position; see <http://patriot.net/~shmuel/resume/brief.html>
We don't care. We don't have to care, we're Congress.
(S877: The Shut up and Eat Your spam act of 2003)
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,