In
<CAFMxNW+NmuenEh0Tem8RnQdZ=jtgauuhsoilq6iussgrltr...@mail.gmail.com>,
on 08/07/2012
   at 12:03 PM, Sam Siegel <[email protected]> said:

>An 0c7 is a data exception error detected by the hardware.

No; it is an ABEND detected by the Program FLIH when there is no SPIE
to catch interupt code 7.

>Without examining the data and software, it is not possible to make
>a definitive statement regarding the cause of the error.

Wrong; the cause of the error is treating data as decimal without
validating them.
 
-- 
     Shmuel (Seymour J.) Metz, SysProg and JOAT
     ISO position; see <http://patriot.net/~shmuel/resume/brief.html> 
We don't care. We don't have to care, we're Congress.
(S877: The Shut up and Eat Your spam act of 2003)

----------------------------------------------------------------------