I am trying to add a second CPC to my environment and I am having an issue getting my 2 z14s to connect via CE LR. On the 'new' system I see CSYSTEM and LSYSTEM as expected but on the other side (current production) I can only see CSYSTEM.
I have cleaned cables, toggled pchids(vchids), wrap tested the ports and everything else I can think to do. I am going between buildings using patch panels/dark fiber. The SEs are at the same MCL bundle levels. I have sent a PMR to IBM, they have reviewed the logs and the IOCDS's on both CPCs but have found nothing wrong. Does anyone have any suggestions? Thank you, Jennifer ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN