Hi

The CSYSTEM and LSYSTEM is an actual status via the service element while 
looking at the channel problem determination of the VCHPD.

The weird part is, the new system can see both the local (itself) and 
connecting system (production) but the current system running production can 
only see the connecting system but not itself.

I've verified the IOCDS and also sent it to IBM to make sure I'm not missing 
something. They have found nothing wrong after checking the SE log and the 
IOCDS from both machines.

When I display the channel on any running lpar (D M=CHP(xx)), I receive 
physical - not operational logical - online.
I"ve taken the channels offline via MVS commands on all active lpars as well as 
the CFs and then brought them back online but it still won't give me a physical 
online.

I'm at a total loss as to where to go or what to do to fix this issue.

Thanks,
Jennifer

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to