Gadi, I think the userid is not checked until the password is available. You can confirm this by entering a userid that is not valid. You will still get a password prompt.
So it looks to me that once the pair are available they are sent to RACF; where you are getting a wait. You need to understand why RACF/ACF2/TSS is taking so long with the authentication. Lennie Dymoke-Bradshaw https://rsclweb.com "Dance like no one is watching. Encrypt like everyone is" -----Original Message----- From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Gadi Ben-Avi Sent: 19 August 2021 11:22 To: [email protected] Subject: FTP problem Hi, We are in the midst of a DR test. A user is complaining that they are have problems using ftp. When the issue the ftp command from the command line in windows, they get the prompt for the user name almost immediately. Once the user enters the password and presses enter, it takes over a minute to get the prompt for the password. Has anyone encountered this problem. We do not have a similar problem on our production system. The production system is a z15-t02. The LPAR has 92 GB of storage. The DR system is a z13s. The LPAR has 16GB of storage. Both are running z/OS 2.3. Any help would be appreciated. Thanks Gadi ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN