Hello, We recently acquired TACM (Tivoli Adanced Catalog Management).
To use its "MERGECAT WHILE-OPEN" functionality, we would have to properly configure GRS (we presently have GRS=NONE in IEASYSxx).
I set GRS=START and GRSRNL=00 in IEASYSxx, but when I IPL the system I get the following message :
ISG157D SYSTEM IN MONOPLEX MODE WITH NO GRS CTC DEFINITIONS. RELOAD THE SYSTEM OR REPLY NONE TO CONTINUE THE IPL.
Is it possible to configure GRS on a MONOPLEX without physical CTCs ? Regards, Frederic Mancini ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN