I pasted below information from the “MVS Planning: Global Resource Serialization” manual for z/OS 2.5. So based on what the manual says you need to have CTCs that GRS will manage. Just out of curiosity is there going to be more then one lpar using this software?
How global resource serialization works. Depending on the level of z/OS and XCF environment the systems are running in, sysplex or non-sysplex, a global resource serialization complex consists of one or more systems: • Connected to each other in a ring configuration through: – XCF signaling paths, through CTC or coupling facility – Global resource serialization managed channel-to-channel (CTC) adapter - Systems in the same sysplex must use XCF signaling - Non-sysplex or monplex systems must use GRS-managed CTCs to communicate • Connected to each other in a star configuration through: – XCF signaling paths, through CTC or coupling facility – A GRS coupling facility lock structure Paul -----Original Message----- From: IBM Mainframe Discussion List <[email protected]> On Behalf Of Mark Jacobs Sent: Thursday, June 20, 2024 8:06 AM To: [email protected] Subject: Re: GRS in MONOPLEX without physical CTCs ? Being in a monoplex I assume no. Mark Jacobs Sent from ProtonMail, Swiss-based encrypted email. GPG Public Key - https://api.protonmail.ch/pks/lookup?op=get&[email protected] On Thursday, June 20th, 2024 at 9:04 AM, Seymour J Metz <[email protected]> wrote: > Do you have a CF LPAR? > > -- > Shmuel (Seymour J.) Metz > http://mason.gmu.edu/~smetz3 > עַם יִשְׂרָאֵל חַי > נֵ֣צַח יִשְׂרָאֵ֔ל לֹ֥א יְשַׁקֵּ֖ר > > ________________________________________ > From: IBM Mainframe Discussion List [email protected] on behalf > of MANCINI Frédéric (80) [email protected] > > Sent: Thursday, June 20, 2024 8:29 AM > To: [email protected] > Subject: GRS in MONOPLEX without physical CTCs ? > > Hello, > > We recently acquired TACM (Tivoli Adanced Catalog Management). > > To use its "MERGECAT WHILE-OPEN" functionality, we would have to > properly configure GRS (we presently have GRS=NONE in IEASYSxx). > > I set GRS=START and GRSRNL=00 in IEASYSxx, but when I IPL the system I > get the following message : > > ISG157D SYSTEM IN MONOPLEX MODE WITH NO GRS CTC DEFINITIONS. RELOAD > THE SYSTEM OR REPLY NONE TO CONTINUE THE IPL. > > Is it possible to configure GRS on a MONOPLEX without physical CTCs ? > > Regards, > > Frederic Mancini > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send > email to [email protected] with the message: INFO IBM-MAIN > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send > email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN