Perhaps directly related to the MPF doc that Ed linked to, but I've run into 
the 10 character max when trying to set a MSGID SLIP. For example:


11 characters:

SLIP SET,ID=AVGO,MSGID=CHARS6789AB,A=SVCD,EN,E                       
0185 IEE836D SLIP ID=AVGO  ERROR - MSGID    - INVALID OPERAND LENGTH

10 characters:

SLIP SET,ID=AVGO,MSGID=CHARS6789A,A=SVCD,EN,E   
IEE727I SLIP TRAP ID=AVGO SET                   

... so having a product that issued such messages could make serviceability a 
bit more difficult.

===============================