Nope.

+         ICM   R2,B'1111',0(14)       IS A BUFFER AVAILABLE
+         BZ    *+10                NO,RETURN ZERO          
+         MVC   0(4,14),0(R2)       

Charles
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Bill Godfrey
Sent: Saturday, June 01, 2013 9:30 AM
To: [email protected]
Subject: Re: Examples of getbuf and build usage

On Thu, 30 May 2013 19:12:54 -0400, Micheal Butz wrote:

>Would anyone have examples of
>Getbuf used with BSAM read
>
>I think it might help my problem
>
Are your buffer addresses above the line? If so, they shouldn't be. GETBUF gets 
a 24-bit BUFCB address from the DCB using ICM 14,7,21(1).

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to