Look at the pOPs. On Mon, 23 Feb 2026 12:26:05 -0500 Joseph Reichman <[email protected]> wrote:
:>Hi :> :>Was just looking at a edit (ED) instruction :> :>The second operand which by the fact pattern was 12 bytes would mean that operand 2 would have to be 7 bytes packed :> :>Looking at this under test :> :>The 7 bytes are all hex digits in the range of 0 - 9 without a sign :> :>Should of generated a S0C7 -- Binyamin Dissen <[email protected]> http://www.dissensoftware.com Director, Dissen Software, Bar & Grill - Israel ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN