Just on teams at work with Seymour

The receiving field has to have 20 or 21 to get a S0C7




On Mon, Feb 23, 2026 at 2:15 PM Joseph Reichman <[email protected]>
wrote:

> I did
>
> Let me you what I did moved 12 bytes of X’FF’
>
> Into the source followed 12 bytes of X’00’ into the receiving field
>
> ED       Receiving,source
>
> Under test it executes without a problem
>
> Thanks
>
> Get Outlook for iOS <https://aka.ms/o0ukef>
> ------------------------------
> *From:* IBM Mainframe Discussion List <[email protected]> on
> behalf of Binyamin Dissen <[email protected]>
> *Sent:* Monday, February 23, 2026 2:00:57 PM
> *To:* [email protected] <[email protected]>
> *Subject:* Re: ED fail to generate 0C7
>
> Look at the pOPs.
>
> On Mon, 23 Feb 2026 12:26:05 -0500 Joseph Reichman
> <[email protected]> wrote:
>
> :>Hi
> :>
> :>Was just looking at a edit (ED) instruction
> :>
> :>The second operand which by the fact pattern was 12 bytes would mean
> that operand 2 would have to be 7 bytes packed
> :>
> :>Looking at this under test
> :>
> :>The 7 bytes are all hex digits in the range of 0 - 9 without a sign
> :>
> :>Should of generated a S0C7
>
> --
> Binyamin Dissen <[email protected]>
> http://www.dissensoftware.com
>
> Director, Dissen Software, Bar & Grill - Israel
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to