The receiving field needs to have hex 20 and 21s for a s0C7 Get Outlook for iOS<https://aka.ms/o0ukef> ________________________________ From: [email protected] <[email protected]> Sent: Monday, February 23, 2026 3:35:59 PM To: IBM Mainframe Discussion List <[email protected]> Cc: Joseph Reichman <[email protected]> Subject: Re: ED fail to generate 0C7
You need to show us what the fields contain. On 24/02/2026 04:26, Joseph Reichman wrote: > Hi > > Was just looking at a edit (ED) instruction > > The second operand which by the fact pattern was 12 bytes would mean > that operand 2 would have to be 7 bytes packed > > Looking at this under test > > The 7 bytes are all hex digits in the range of 0 - 9 without a sign > > Should of generated a S0C7 ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN