The point was that the error was so severe that it caused a wait state and 
required a standalone dump for analysis. Typically, IPL should proceed at least 
to activate the console and place the message on the console. IBM tries to make 
the system at least somewhat viable even if it cannot provide full 
functionality. Wait state codes without messages are typically a last resort 
situation.

SYS1.LPALIB was probably after the coding error which would have made critical 
LPA programs unavailable.

Jon Perryman.



>________________________________
> From: saurabh khandelwal <[email protected]>
>
>
>
>Yes, I have specified CLPA in IEASYSxx . But as Radoslaw
>mentioned, I think comment line can not be part of LPALAT memberĀ  . So ,
>this could only be a issue.
>

----------------------------------------------------------------------