Hello, Was CLPA specified in IEASYSxx when you IPL'd first time ? .If not , that could lead to a wait 064
If not , I am wondering how you got a wait 064 for syntax error in LPALSTxx . On Monday, October 21, 2013 3:25 PM, saurabh khandelwal <[email protected]> wrote: Hello, In my LPALST member, while adding dataset for CICS 5.1 , rather then removing entry for older CICS 4.2, I simply commented CICS 4.2 dataset line like below. /* SYS1.CICS41.SDFHLPA, And added CICS 5.1 dataset SYS1.CICS51.SDFHLPA. I think, this is only reason for this 064 wait code. But at last problem resolved. Thanks for all help. Regards Saurabh On Sun, Oct 20, 2013 at 6:30 PM, Peter Relson <[email protected]> wrote: > >Problem has been resolved. The issue was with > >syntax issue in LPALST parmlib member . > > Can you please explain exactly what the issue was? A syntax error in > LPALST will not ordinarily result in a program check WAIT 064 unless it > meant that your LPALST did not have a data set that the system requires > during IPL. > > Peter Relson > z/OS Core Technology Design > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > -- Thanks & Regards Saurabh Khandelwal ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN