On Fri, 13 Jun 2014 20:23:15 +0000, Staller, Allan <[email protected]> 
wrote:

>I you look a little further into the process, there is a later reply "reply 
>down
> when system has been reset" (or something similar).  
>IF the LPAR that issued the VARY XCF, is in fact the one that has been reset, 
>you would have to find another console to actually reply 'DOWN" from. 
> 
>Other than that, I do not believe it will make any difference in the end.

You can VERY XCF,sysname,OFFLINE from the system you are taking out
of the sysplex and not get those annoying messages if you put an
SFM policy in place.  

--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS  
ITIL v3 Foundation Certified   
mailto:[email protected]                                       
Mark's MVS Utilities: http://www.mzelden.com/mvsutil.html 
Systems Programming expert at http://search390.techtarget.com/ateExperts/
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN