On Thu, Aug 7, 2014 at 2:07 PM, Tim Deller <[email protected]> wrote:

> I would use ENQ
>
> 1. Add a DD statement to the job that you want to test for.
>     //TESTDD DD DSN=hlq.jobname.LOCK,DISP=(NEW,DELETE,DELETE),etc.
> 2. Issue ENQ with TEST on SYSDSN for the lock dataset name from the
> assembler cics program.
>
> Thanks,
> Tim Deller
>
>
> Tim thanks, that sounds like a goer. I'll do some further investigation. I
presume the ENQ would need to have a scope of SYSTEMS for a SYSPLEX. Would
a scope of SYSTEMS also cover a single z/OS image. It's years since it did
any stuff like this.

Jim Mc

----------------------------------------------------------------------