IXC466I INBOUND SIGNAL CONNECTIVITY ESTABLISHED WITH SYSTEM IPO2 245      
         VIA DEVICE 0342 WHICH IS CONNECTED TO DEVICE 0412                 
 IXC466I OUTBOUND SIGNAL CONNECTIVITY ESTABLISHED WITH SYSTEM IPO2 246     
         VIA DEVICE 0343 WHICH IS CONNECTED TO DEVICE 0413                 
 IXC466I INBOUND SIGNAL CONNECTIVITY ESTABLISHED WITH SYSTEM IPO2 247      
         VIA DEVICE 0340 WHICH IS CONNECTED TO DEVICE 0410                 
 IXC466I OUTBOUND SIGNAL CONNECTIVITY ESTABLISHED WITH SYSTEM IPO2 248     
         VIA DEVICE 0341 WHICH IS CONNECTED TO DEVICE 0411                 
 PXM4704 XMANAGER PLEXGRPX GRP=         MEM=                               
 PXM4704 XMANAGER PLEXGRPX GRP=         MEM=                               
 PXM4705 XMANAGER PLEXGRPX NEW=00 OLD=00 TYPE=0B                           
 PXM4705 XMANAGER PLEXGRPX NEW=00 OLD=00 TYPE=0B                           
 PXM4704 XMANAGER PLEXGRPX GRP=         MEM=                               
 PXM4705 XMANAGER PLEXGRPX NEW=00 OLD=00 TYPE=0B                           
 ISG011I SYSTEM IPO2 - JOINING GRS COMPLEX                                 
 IXC467I RESTARTING PATHIN DEVICE 0340 256                                 
         USED TO COMMUNICATE WITH SYSTEM IPO2                              
         RSN: INTERVENTION REQUIRED                                        
 IXC467I RESTARTING PATHIN DEVICE 0342 257                                 
         USED TO COMMUNICATE WITH SYSTEM IPO2                              
         RSN: INTERVENTION REQUIRED                                        
 IXC467I RESTARTING PATHOUT DEVICE 0341 258                                
         USED TO COMMUNICATE WITH SYSTEM IPO2                              
         RSN: INTERVENTION REQUIRED                                        
 IXC467I RESTARTING PATHOUT DEVICE 0343 260                                
         USED TO COMMUNICATE WITH SYSTEM IPO2                              
         RSN: INTERVENTION REQUIRED                                        
*18 IXC409D SIGNAL PATHS BETWEEN IPO2 AND IPO1 ARE LOST. REPLY RETRY OR    
 SYSNAME=SYSNAME OF THE SYSTEM TO BE REMOVED.                              
 CTM916W PROGRAM CTMCKP   WAITING FOR CTM.CKPT      10 SEC                 
 CTM916W PROGRAM CTMCKP   WAITING FOR CTM.CKPT      70 SEC                 
 R 18,SYSNAME=IPO2,DOWN                                                    
 IEE600I REPLY TO 18 IS;SYSNAME=IPO2,DOWN                                  
*19 IXC417D CONFIRM REQUEST TO REMOVE IPO2 FROM THE SYSPLEX. REPLY         
 SYSNAME=IPO2 TO REMOVE IPO2 OR C TO CANCEL.                               
 R 19,SYSNAME=IPO2                                                         
 IEE600I REPLY TO 19 IS;SYSNAME=IPO2                                       
 IXC101I SYSPLEX PARTITIONING IN PROGRESS FOR IPO2 REQUESTED BY 270        
 XCFAS. REASON: SYSTEM ENTERED WAIT STATE                                  
*ISG178E GLOBAL RESOURCE SERIALIZATION HAS BEEN DISRUPTED.  GLOBAL         
RESOURCE REQUESTORS WILL BE SUSPENDED.                                   
IXC808I ELEMENTS FROM TERMINATED SYSTEM IPO2 WERE NOT PROCESSED BY 272   
THIS SYSTEM.  ARM COUPLE DATA SET IS NOT AVAILABLE TO THIS SYSTEM.       
IXC105I SYSPLEX PARTITIONING HAS COMPLETED FOR IPO2 273                  
- PRIMARY REASON: SYSTEM ENTERED WAIT STATE                              
- REASON FLAGS: 000022                                                   
ISG179I SYSTEM IPO1 INITIATED AUTO RESTART PROCESSING.                   
ISG175I SYSTEM IPO1 RESTARTED GLOBAL RESOURCE SERIALIZATION.             
ISG011I SYSTEM IPO2 - BEING PURGED FROM GRS COMPLEX                      
ISG013I SYSTEM IPO2 - PURGED FROM GRS COMPLEX                            

But if I try to activate IPO2 after this, I get same IXC409I message.

Anne D. Crabtree
System Programmer 
WV Office of Technology Data Center
1900 Kanawha Blvd East
Bldg 6, Room B-110
Charleston, WV  25305
(304)957-8292 
(304)558-1441 fax


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Lizette Koehler
Sent: Sunday, July 12, 2015 12:45 PM
To: [email protected]
Subject: Re: XCF HELP!

A question or two.
Did you wait long enough when the IXC409D was produced?
The system continues and will process the response when entered.
Cross-system coupling facility (XCF) tries to restart the signaling path. If 
XCF restores connectivity, the message will be deleted before it is answered. 
If XCF cannot fully restore connectivity between the two systems, the system 
issues message IXC409D again.


Did you see any other IXC message?
IXC402D or IXC102A, XCF signaling connectivity to the removed system is no 
longer relevant and the system deletes the message.

Could you post the RSP to the IXC409D you entered?  And any additional messages 
that occurred after that?


Not sure what is going on at this point.  So, the worst case scenario would be 
a sysplex wide COLD start.  All LPARs down, then one up with INITIAL, the rest 
JOIN.  But that is not necessarily what is needed, just what might be the very 
worst thing that might need to be done.

Nice webpage with XCF Commands summary
http://www.oocities.org/smtwango/MAINFRAME/MFCOMMANDS/sysplexcmd.html



Thanks

Lizette

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] 
> On Behalf Of Crabtree, Anne D
> Sent: Sunday, July 12, 2015 9:18 AM
> To: [email protected]
> Subject: XCF HELP!
> 
> For the first time ever, when shutting down an LPAR in a sysplex, I 
> forgot
to
> issue the V XCF,lparname,OFF!
> 
> Now, I can't get that LPAR to join the sysplex.  Luckily, the 
> important
LPAR is
> up.  The second LPAR is supposed to be in a sysplex and I am the only 
> one using it.  It currently has z/os 2.1 running on  it.
> 
> I keep getting error:
> IXC409D
> SIGNAL PATHS BETWEEN sysname1 AND sysname2 ARE LOST. REPLY RETRY OR 
> SYSNAME=SYSNAME OF THE SYSTEM TO BE REMOVED.
> 
> I've tried to RETRY and to give it SYSNAME that's down, but nothing helps!
> I'm sure there's some SETXCF command I need to do, but I've never done 
> this before so I'm unsure.
> 
> I put a question in to IBM but won't hear back till tomorrow.  It 
> would be
nice
> if someone is out there and can help me!!
> 
> Anne D. Crabtree
> System Programmer
> WV Office of Technology Data Center
> 1900 Kanawha Blvd East
> Bldg 6, Room B-110
> Charleston, WV  25305
> (304)957-8292
> (304)558-1441 fax
> 
> 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to