Ma'am, I believe that XCF / GRS are having problems with your CDS's and or, perhaps even alternate CDS's.
I suggest checking XCF and GRS on all systems while this is in progress, with commands such as D XCF,S,ALL and D GRS to find their status. Please check for INACTIVE and or QUIESCE'd paths .. if this is the case .. you might have to issue PATHIN / OUT to recover. XCF has to be has to be able to signal other images. If you find problematic paths... please give GRS enough time (I usually ask that you give it at least ten to fifteen minutes ... just to be on the safe side) to try and recover. If you still see GRS INACTIVE or QUIESCE'd status thereafter, try to QUIESCE the 'dead' system (IPO2 in this instance I think). If the above is unsuccessful, try to SETXCF STOP / START POLICY. Kind Regards, Jim Thomas 617-233-4130 (mobile) 636-327-7333 (res / wrk) [email protected] (pvt email) -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Crabtree, Anne D Sent: Sunday, July 12, 2015 11:52 AM To: [email protected] Subject: Re: XCF HELP! IXC466I INBOUND SIGNAL CONNECTIVITY ESTABLISHED WITH SYSTEM IPO2 245 VIA DEVICE 0342 WHICH IS CONNECTED TO DEVICE 0412 IXC466I OUTBOUND SIGNAL CONNECTIVITY ESTABLISHED WITH SYSTEM IPO2 246 VIA DEVICE 0343 WHICH IS CONNECTED TO DEVICE 0413 IXC466I INBOUND SIGNAL CONNECTIVITY ESTABLISHED WITH SYSTEM IPO2 247 VIA DEVICE 0340 WHICH IS CONNECTED TO DEVICE 0410 IXC466I OUTBOUND SIGNAL CONNECTIVITY ESTABLISHED WITH SYSTEM IPO2 248 VIA DEVICE 0341 WHICH IS CONNECTED TO DEVICE 0411 PXM4704 XMANAGER PLEXGRPX GRP= MEM= PXM4704 XMANAGER PLEXGRPX GRP= MEM= PXM4705 XMANAGER PLEXGRPX NEW=00 OLD=00 TYPE=0B PXM4705 XMANAGER PLEXGRPX NEW=00 OLD=00 TYPE=0B PXM4704 XMANAGER PLEXGRPX GRP= MEM= PXM4705 XMANAGER PLEXGRPX NEW=00 OLD=00 TYPE=0B ISG011I SYSTEM IPO2 - JOINING GRS COMPLEX IXC467I RESTARTING PATHIN DEVICE 0340 256 USED TO COMMUNICATE WITH SYSTEM IPO2 RSN: INTERVENTION REQUIRED IXC467I RESTARTING PATHIN DEVICE 0342 257 USED TO COMMUNICATE WITH SYSTEM IPO2 RSN: INTERVENTION REQUIRED IXC467I RESTARTING PATHOUT DEVICE 0341 258 USED TO COMMUNICATE WITH SYSTEM IPO2 RSN: INTERVENTION REQUIRED IXC467I RESTARTING PATHOUT DEVICE 0343 260 USED TO COMMUNICATE WITH SYSTEM IPO2 RSN: INTERVENTION REQUIRED *18 IXC409D SIGNAL PATHS BETWEEN IPO2 AND IPO1 ARE LOST. REPLY RETRY OR SYSNAME=SYSNAME OF THE SYSTEM TO BE REMOVED. CTM916W PROGRAM CTMCKP WAITING FOR CTM.CKPT 10 SEC CTM916W PROGRAM CTMCKP WAITING FOR CTM.CKPT 70 SEC R 18,SYSNAME=IPO2,DOWN IEE600I REPLY TO 18 IS;SYSNAME=IPO2,DOWN *19 IXC417D CONFIRM REQUEST TO REMOVE IPO2 FROM THE SYSPLEX. REPLY SYSNAME=IPO2 TO REMOVE IPO2 OR C TO CANCEL. R 19,SYSNAME=IPO2 IEE600I REPLY TO 19 IS;SYSNAME=IPO2 IXC101I SYSPLEX PARTITIONING IN PROGRESS FOR IPO2 REQUESTED BY 270 XCFAS. REASON: SYSTEM ENTERED WAIT STATE *ISG178E GLOBAL RESOURCE SERIALIZATION HAS BEEN DISRUPTED. GLOBAL RESOURCE REQUESTORS WILL BE SUSPENDED. IXC808I ELEMENTS FROM TERMINATED SYSTEM IPO2 WERE NOT PROCESSED BY 272 THIS SYSTEM. ARM COUPLE DATA SET IS NOT AVAILABLE TO THIS SYSTEM. IXC105I SYSPLEX PARTITIONING HAS COMPLETED FOR IPO2 273 - PRIMARY REASON: SYSTEM ENTERED WAIT STATE - REASON FLAGS: 000022 ISG179I SYSTEM IPO1 INITIATED AUTO RESTART PROCESSING. ISG175I SYSTEM IPO1 RESTARTED GLOBAL RESOURCE SERIALIZATION. ISG011I SYSTEM IPO2 - BEING PURGED FROM GRS COMPLEX ISG013I SYSTEM IPO2 - PURGED FROM GRS COMPLEX But if I try to activate IPO2 after this, I get same IXC409I message. Anne D. Crabtree System Programmer WV Office of Technology Data Center 1900 Kanawha Blvd East Bldg 6, Room B-110 Charleston, WV 25305 (304)957-8292 (304)558-1441 fax -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Lizette Koehler Sent: Sunday, July 12, 2015 12:45 PM To: [email protected] Subject: Re: XCF HELP! A question or two. Did you wait long enough when the IXC409D was produced? The system continues and will process the response when entered. Cross-system coupling facility (XCF) tries to restart the signaling path. If XCF restores connectivity, the message will be deleted before it is answered. If XCF cannot fully restore connectivity between the two systems, the system issues message IXC409D again. Did you see any other IXC message? IXC402D or IXC102A, XCF signaling connectivity to the removed system is no longer relevant and the system deletes the message. Could you post the RSP to the IXC409D you entered? And any additional messages that occurred after that? Not sure what is going on at this point. So, the worst case scenario would be a sysplex wide COLD start. All LPARs down, then one up with INITIAL, the rest JOIN. But that is not necessarily what is needed, just what might be the very worst thing that might need to be done. Nice webpage with XCF Commands summary http://www.oocities.org/smtwango/MAINFRAME/MFCOMMANDS/sysplexcmd.html Thanks Lizette > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Crabtree, Anne D > Sent: Sunday, July 12, 2015 9:18 AM > To: [email protected] > Subject: XCF HELP! > > For the first time ever, when shutting down an LPAR in a sysplex, I > forgot to > issue the V XCF,lparname,OFF! > > Now, I can't get that LPAR to join the sysplex. Luckily, the > important LPAR is > up. The second LPAR is supposed to be in a sysplex and I am the only > one using it. It currently has z/os 2.1 running on it. > > I keep getting error: > IXC409D > SIGNAL PATHS BETWEEN sysname1 AND sysname2 ARE LOST. REPLY RETRY OR > SYSNAME=SYSNAME OF THE SYSTEM TO BE REMOVED. > > I've tried to RETRY and to give it SYSNAME that's down, but nothing helps! > I'm sure there's some SETXCF command I need to do, but I've never done > this before so I'm unsure. > > I put a question in to IBM but won't hear back till tomorrow. It > would be nice > if someone is out there and can help me!! > > Anne D. Crabtree > System Programmer > WV Office of Technology Data Center > 1900 Kanawha Blvd East > Bldg 6, Room B-110 > Charleston, WV 25305 > (304)957-8292 > (304)558-1441 fax > > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ----- No virus found in this message. Checked by AVG - www.avg.com Version: 2015.0.6081 / Virus Database: 4392/10215 - Release Date: 07/12/15 ----- No virus found in this message. Checked by AVG - www.avg.com Version: 2015.0.6081 / Virus Database: 4392/10215 - Release Date: 07/12/15 ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN