An example from yesterday. Not sure if this message is owned by USS or not
but it sure fits the pattern you describe. Pasted in its entirety without
editing.

GIM37150S

SMP/E for z/OS Messages, Codes, and Diagnosis
GA32-0883-01 


GIM37150S
THE keyword KEYWORD IS MISSING OR INVALID.
Explanation

keyword
missing or invalid keyword
A keyword required in the input data set is missing or a specified keyword
is invalid.

System action

Processing stops.

Programmer response

Correct the error and rerun the job.

Charles

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Edward Gould
Sent: Tuesday, September 06, 2016 9:12 PM
To: [email protected]
Subject: Re: FTP on z/OS sucks

> On Sep 6, 2016, at 1:21 PM, Paul Gilmartin
<[email protected]> wrote:
> 
> On 2016-09-06 12:02, Edward Gould wrote:
>> 
>> ... The same can be said about the OMVS people. Just take a look at the
M&C for both products and it will make you sick. Compared to MVS the manuals
are quite primitive.
>> 
> Take care judging a product by the thickness of its manual.  That 
> ignores the maxim, "Simpler is better."
> 
> - gil
Gil:

Never mind about thickness. I am talking about a message that is somewhat
clear and a decent programmer response. Its been a few years but I will try
and remember the message & response. Message content: Bad parameters
                 programmer response: Correct bad parameters

Its like the old proverbial message: Call you systems programmer.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to